Pad Mounted Transformer

500 kva Pad Mounted Transformer

150 kva pad mounted transformer
  • Junengda 500 kva Pad Mounted Transformer Overview>>>

The Junengda 500 kVA Pad-Mounted Transformer delivers robust, reliable power distribution for urban grids and industrial facilities worldwide. Engineered with corrosion-resistant enclosures and advanced safety systems, it meets stringent global standards like IEC and IEEE, ensuring durability in diverse environments. Trusted across Europe, Southeast Asia, and the Middle East, this transformer optimizes space efficiency and operational resilience for modern energy networks.

  • Junengda 500 kva Pad Mounted Transformer Technical Specifications>>>

RatedPower
(KVA)
HV(KV) LV(KV) Loss(w) Dimension(cm)
no-loadloss(w) on-loadloss(W) W D H
75 34.5 19.92 13.8 13.2 12.47 7.62  7.2 240V480V 480V/277V
600V/347V
180 1250 1390 910 1430
112.5 200 1500 1420 920 1430
150 280 2200 1510 980 1530
225 400 3050 1600 1000 1660
300 480 3650 1660 1080 1680
500 680 5100 1810 1160 1790
750 980 7500 2030 1300 2030
1000 1150 10300 1651 1549 1854
1500 1640 14500 2210 1470 2150
2000 2160 20645 2380 1600 2220
2500 2680 27786 2480 1650 2330
  • Junengda 500 kva Pad Mounted Transformer Feature>>>

Global Certifications & Compliance

Meets rigorous IEC, IEEE, and CE standards, ensuring the Junengda 500 kVA pad-mounted transformer operates safely and reliably across international markets.

Main Export Countries

Proven in power distribution networks across Europe, Southeast Asia, and the Middle East, making the Junengda transformer a trusted global solution.

Urban & Industrial Applications

Optimally designed for underground distribution systems in cities, commercial complexes, and industrial facilities where the 500 kVA pad-mounted transformer excels in space efficiency and safety.

Robust Corrosion-Resistant Structure

Features a tamper-proof, stainless steel or galvanized carbon steel enclosure, protecting the Junengda pad-mounted transformer from harsh environments and vandalism.

Advanced Monitoring & Safety Systems

Incorporates integrated fault detection and dry-type/VPI transformer technology, enhancing the 500 kVA transformer’s operational safety and enabling smart grid readiness.

  • Junengda 500 kva Pad Mounted Transformer Advantage>>>

Enhanced Safety

Junengda’s transformer integrates advanced fault protection and arc-resistant enclosures, reducing electrical hazards by over 30% and ensuring compliance with global safety standards like IEC and IEEE.

Superior Operational Stability

Leveraging precision-engineered cores and adaptive cooling, it minimizes voltage fluctuations by 12.5% and extends continuous operation life even in high-penetration renewable energy grids.

Low Maintenance Costs

With self-diagnostic sensors and corrosion-resistant materials, maintenance frequency drops by 40%, slashing long-term operational expenses.

High Space Efficiency

Compact, pad-mounted design reduces footprint by 25% versus conventional units, ideal for urban or space-constrained installations without sacrificing 500 kVA capacity.

Eco-Friendly Performance

Non-toxic, biodegradable coolant and >99% recyclable steel construction cut carbon footprint by 15%, aligning with global sustainability goals.

Energy Efficiency Optimized

Nano-crystalline core technology achieves 98.5% efficiency—exceeding DOE 2023 standards—reducing grid losses by 26.3% and lowering energy costs

 

Why choose Junengda?

Choose the Junengda product for a resilient, certified, and intelligent power distribution asset.

 

  • Junengda 500 kva Pad Mounted Transformer Case>>>

1.Urban Underground Distribution Network in Dubai, UAE

Upgrade of Downtown Burj District power infrastructure. Installed seven products in confined underground vaults. These units supported high-density load demands while withstanding desert temperatures of 50°C+ due to corrosion-resistant enclosures and forced-air cooling technology. The compact design minimized spatial footprint, enabling seamless integration into existing municipal networks without civil engineering modifications.

2.Industrial Zone Expansion in Ho Chi Minh City, Vietnam

Power stability enhancement for Saigon Hi-Tech Park’s manufacturing facilities.Junengda Solution: Deployed 12 units of products to replace aging infrastructure. Critical for continuous operation of semiconductor production lines, the transformers’ IP67 protection prevented moisture ingress during monsoon seasons. Dual-power automatic switching (inspired by grid reliability systems) ensured zero downtime during utility outages, sustaining 24/7 operations for multinational tenants.

3.Commercial Complex in Riyadh, Saudi Arabia

Energy system modernization for King Abdullah Financial District.Junengda Solution: Twenty products delivered vibration-damped, low-noise operation (<65 dB) beneath high-traffic plazas. Their fire-retardant tanks and fault-current limiting design aligned with local safety regulations, while loop-feed configurations maintained power to retail/office towers during maintenance. Result: 30% reduction in outage-related revenue losses for tenants.

4.Solar Microgrid Integration in Santiago, Chile

Hybrid renewable energy deployment for Quilicura residential township.Junengda Solution: Eight products interfaced rooftop solar arrays with the main grid. Engineered for bidirectional power flow and voltage stabilization, they enabled surplus solar export during peak generation. Dry-type insulation eliminated fire risks in arid climates, and remote monitoring cut maintenance costs by 40% through predictive diagnostics.

  • Junengda 500 kva Pad Mounted Transformer FAQ>>>

Q1: What is the primary application of Junengda’s 500 kVA pad-mounted transformer?

Junengda’s product is designed for underground power distribution systems, ideal for commercial complexes, residential subdivisions, and industrial facilities. Its compact, corrosion-resistant enclosure ensures reliable power delivery in diverse environments.

Q2: How does Junengda ensure the safety of its 500 kVA pad-mounted transformers?

Safety is engineered into every Junengda product. It features robust overvoltage protection against both internal surges (e.g., switching operations) and atmospheric surges (e.g., lightning strikes), preventing insulation damage and equipment failure1. Grounding resistance adheres to ≤10Ω standards to eliminate electrical hazards.

Q3: What protection standards does the transformer’s enclosure meet?

The product enclosure is rated IP68 (Ingress Protection), offering complete dust resistance and waterproofing for submerged conditions. Heavy-gauge steel construction and corrosion-proof coatings extend its lifespan in harsh climates.

Q4: Can Junengda’s 500 kVA transformer handle voltage fluctuations?

Yes. Our pad-mounted transformers include on-load tap changers (OLTC) to adjust voltage levels ±5%–10%, ensuring stable output despite grid fluctuations. This prevents voltage-related disruptions for critical loads.

Q5: What grounding requirements apply to installation?

Per international safety standards, the grounding resistance must not exceed 10Ω. Junengda provides integrated grounding terminals and detailed guidelines to achieve compliant, low-resistance grounding systems.

Q6: Are these transformers suitable for high-lightning areas?

Absolutely. Junengda pad-mounted transformers incorporate lightning arresters and shielded windings to dissipate surge currents. Maintain a safe distance (≥10 meters) during storms to avoid step-voltage risks.

Q7: What maintenance does a Junengda 500 kVA pad-mounted transformer require?

Routine maintenance is minimal. We recommend annual inspections of bushings, coolant levels (for liquid-filled units), and enclosure integrity. Junengda transformers are designed for >30-year service with proper upkeep.

Q8: Does Junengda offer customization for specific project needs?

Yes. Customize voltage ratings (e.g., 11kV/400V, 33kV/480V), cooling methods (liquid or dry-type), and enclosure dimensions. Contact our engineering team for bespoke solutions.

Q9: What certifications do Junengda transformers hold?

All 500 kVA pad-mounted transformers comply with IEC 60076, IEEE C57.12.20, and ANSI standards. Optional certifications (UL, CE) are available for regional markets.